PAG: Investigating I–V Characteristics (OCR GCSE Physics A (Gateway))
Revision Note
PAG: Investigating I–V Characteristics
Aim of the Experiment
The aim of the experiment is to use circuit diagrams to construct appropriate circuits to investigate the I–V characteristics of a variety of circuit elements
These include a fixed resistor at a constant temperature, a lamp and diode
Variables:
Independent variable = Potential difference, V
Dependent variable = Current, I
Control variables:
Potential difference of the power supply
Use of the same equipment eg. wires, diodes
Equipment List
Ammeter
Voltmeter
Variable resistor
Fixed resistor (between 100 Ω and 500 Ω)
Filament lamp
Diode
Voltage Supply
Connecting Wires
Resolution of measuring equipment:
Variable resistor = 0.005 Ω
Voltmeter = 0.1 V
Ammeter = 0.01 A
Method
Circuit diagram of the apparatus set up. The fixed resistor will be replaced by a filament lamp and diode
Set up the circuit as shown with the fixed resistor
Vary the voltage/potential difference across the component by changing the resistance of the variable resistor, using a wide range of voltages (between 8-10 readings). Check the appropriate voltage reading on the voltmeter
For each voltage, record the value of the current from the ammeter 3 times and calculate the average current
Increase the voltage further in steps of 0.5 V and repeat steps 2 and 3
Make sure to switch off the circuit in between readings to prevent heating of the component and wires
Reverse the terminals of the power supply and take readings for the negative voltage (and therefore negative current)
Replace the fixed resistor with the filament lamp, then the diode, repeating the experiment for each
An example of a suitable table might look like this:
Analysis of Results
Plot a graph of average current against potential difference (an I–V graph) for each component
If the I–V graph is a straight line, it is an ohmic conductor. This is expected from the fixed resistor
This means it obeys Ohm's Law: V = IR
If the I–V graph is a curve, it is a non-ohmic conductor. This is expected from the filament lamp and diode
Compare the results from the graphs obtained to the known I–V graphs for the resistor, filament lamp and diode. These should look like:
The expected I-V graphs for the resistor, diode and filament lamp
Evaluating the Experiment
Systematic Errors:
The voltmeter and ammeters should start from zero, to avoid zero error in the readings
Random Errors:
In practice, the voltmeter and ammeter will still have some resistance, therefore the voltages and currents displayed may be slightly inaccurate
The temperature of the equipment could affect its resistance. This must be controlled carefully
Taking multiple readings of the current for each component will provide a more accurate result and reduce uncertainties
Safety Considerations
When there is a high current and a thin wire, the wire will become very hot
Make sure never to touch the wire directly when the circuit is switched on
Switch off the power supply right away if burning is smelled
Make sure there are no liquids close to the equipment, as this could damage the electrical equipment
The components will get hot, especially at higher voltages
Be careful when handling them - especially the filament lamp
Disconnect the power supply in between readings to avoid the components heating up too much