Scanning Tunnelling Microscope (AQA A Level Physics)
Revision Note
Scanning Tunnelling Microscope (STM)
How Does an STM Work?
By the 1980s, many advances had been made in research technology and in physics on the scale of the atom
The scanning tunnelling microscope (STM) was created
This microscope is able to resolve objects just 0.001 nm apart
This means it can produce images showing individual rows of atoms
A probe with a very fine tip (only a few atoms across) is held a few nanometres above the surface of an object
The probe is moved by pieces of equipment called piezoelectric transducers
These are able to move the tip in any direction by tiny increments of 0.001 nm
The probe is held at a constant potential difference with the surface of the sample
Because the tip is so close to the surface of the sample, some electrons are able to jump, or tunnel, to the tip
This produces a tunnelling current which is recorded
To be able to scan this surface to produce an image of it:
When the tip reaches a raised atom, the distance from the tip to the surface decreases, and more electrons tunnel so the tunnelling current increases
Likewise, when the tip reaches a dip in the surface, the tunnelling current decreases because the gap is larger and fewer electrons tunnel
These changes in tunnelling current are used to produce a map of the surface of a sample
Diagram showing the probe of the STM and the sample surface
Due to the potential difference across the gap and its short distance, some electrons tunnel across the gap to the tip of the probe, generating a current. The size of this current depends on the width of the gap it must cross.
Constant Height or Constant Current?
STMs operate in two modes: constant height or constant current
In constant height mode:
The tip does not move vertically up or down while scanning areas
This means that changes in the surface increase or decrease the gap size
The tunnelling current therefore varies
This is used to produce an image of the surface
In constant current mode:
When a change in tunnelling current is detected, the tip moves up or down to keep the current constant
This means the gap size is always the same
The vertical motion of the probe is used to map an image of the surface
Quantum Tunnelling
Quantum tunnelling is a result of the wave-like behaviour of particles such as electrons
The gap between the surface and the tip acts as a barrier for electrons
The amplitude of the matter-wave of the electrons is decreased by this barrier, but on the other side of the gap, this amplitude is non-zero
This effect only occurs if the barrier is weak enough (i.e. the distance is small enough)
This is like thin surfaces not being opaque to visible light because some of the wave can pass through
This results in a current passing from sample to probe
This current is very sensitive to changes in gap distance, which allows the STM to have a great resolving power
Examiner Tips and Tricks
Don't worry, details of quantum tunnelling are not examinable, but a general understanding of why it happens is necessary. The word "quantum" can be intimidating, but it just refers to processes that are a result of the quantisation of things like energy.